We have combined a RTD and a type K thermocouple in one convenient assembly. This sensor is manufactured with high temperature ceramic cement and fiberglass insulated wire, to provide the maximum operating range for the thermocouple. The sensor can be configured to your dimensional requirements or it may be purchased off the shelf with a 3/16" O.D., stainless steel sheath, 2" in length, and 60" of lead wire.

www.thermometricscorp.com

www.thermometrciscorp.com

STANDARD SPECIFICATIONS FOR RTD / THERMOCOUPLE COMBO

Platinum 100 ohm +/- 0.12% @ 0°C (per IEC-751, Class B Accuracy),
Temperature Coefficient = .00385 (per IEC-751 and ASTM E-1137),
2-Wire configuration: 24 AWG, solid nickel wire,
Fiberglass insulation,
T/C according to ANSI Standard Type K,
Special Limits of Accuracy. +/- 1.1°C or +/- 0.40% (which ever is greater),
2-Wire configuration: 24AWG, solid ThermoCouple grade wire,
Fiberglass Insulation,
Ungrounded Junction,
Temperature Range: -50 to 600°C,
Lead Length = 60" +/- 1.00",
Stainless Steel Sheath, 0.188" O.D. +/- 0.003" per ASTM A632,
Sheath Length = 2" +/- 0.10",
Lead Egress sealed with ceramic cement to inhibit the intrusion of moisture,
Each probe etched with lot number to provide traceability.

Changes can be made to;

RTD type, PT 25, 200, 500, 1000, 2000,
nickel, copper, balco, thermistor or semi-conductor temperature elements,
thermocouple type, T, J, E, N, R, S, B, W5,
temperature range, (-250 to +850°C),
accuracy,
wiring configuration,
sheath material,
sheath diameter,
sheath length,
wire material,
lead length,
a variety of fittings are also available.

www.thermometricscorp.com

email Sales Department

Note: Newer versions of web browsers do not allow the following form to work properally. If you have any problems send your requirements via standard e-mail or contact us directly at (818) 886-3755.

 

Name:

Company:

Address:

Phone:

E-Mail:

Picture Number

Sheath Material

RTD Coefficient

Resistance at 0 Celsius

Construction

Wires Per Element

Wire Color Coding

Thermocouple Type

Junction

Construction

Tip Design
Immersion Length
Lead Length
Lead Wire

Protective Covering

Terminations

Terminal Block

Quantity

Comments







RTD Sensors - Thermowells - Thermocouples - Tube Skin Thermocouples - Bayonet Sensors -
Flanges - RTD Temperature Elements - Transmitters - Sensor Pictures - Sanitary Sensors

Search
-Espaņol - Sales / Engineering Support Services - Company Information - Links

Copyright © 1995-2050 Thermometrics Corporation. All rights reserved. Copyright - Privacy Policy - Content Rating